• ASHRAE Handbook Now Includes VRF

    June 5, 2012
    Other topics include: District Heating and Cooling, Ultraviolet Lamp Systems, Fans

    The 2012 ASHRAE Handbook – HVAC Systems and Equipment discusses systems and the equipment that comprises them, including features and differences. It's designed to help system designers and building operators select and use equipment. It contains 52 chapters. The chapter on Variable-Refrigerant-Flow (VRF) Systems describes these systems, their components and applicable standards in detail, and includes a system design example and important guidance on costs, controls and safety. In previous volumes, variable refrigerant flow was covered in the unitary products section.

    “This new chapter covers the A to Z of variable refrigerant flow – from application of VRF to understanding how VRF works and from analyzing a building load in terms of VRF to zoning with VRF,” Paul Doppel, chair of ASHRAE’s technical committee on variable refrigerant flow that wrote the chapter, says. “The chapter offers an excellent overview of VRF technology, including discussion about 2-pipe and 3-pipe system performance during heating operations.”

    The chapter also includes a section that lays out a process for designing with VRF including a load analysis, as well as discussions regarding system expansion and designing systems to meet ASHRAE standard requirements. “Since VRF systems can connect more than 100 percent nominal capacity of indoor units (up to 150 percent in some cases), the chapter also addresses shows how VRF can be used to satisfy changing building conditions with smaller capacity systems by using building diversity and multiple indoor units,” Doppel says.

    Other highlights in the 2012 volume:
    District Heating and Cooling, has an extensive new section on economic comparisons, plus several new detailed examples.

    • Ultraviolet Lamp Systems, has new results from ASHRAE research project RP-1509 on degradation of materials irradiated by UVC energy.
    • The Duct Construction chapter has a rewritten section on duct leakage, and new information on air dispersion systems and factory-built grease duct systems.
    • A chapter on fans, has added descriptions of types of fans and their applications; many upgraded figures; vibration categories, grades and limits; and a complete rewrite and update for the controls section.
    • Thermal Storage, has new content on unitary thermal storage systems (UTSSs), two new detailed sizing examples, several new figures, and extensive new guidance on equipment selection and operation.

    To order, contact ASHRAE Customer Service at 1-800-527-4723 (United States and Canada) or 404-636-8400 (worldwide) or visit at ashrae.org/bookstore.