Latest from Refrigeration

Rheem
engineeredforlifelockupentmrgb
In response to the industry shortage of R-454B cylinders, Rheem to increase the factory charge to minimize disruptions.
May 22, 2025
ACCA
acca_logo
ACCA's R-454B Resource Center addresses challenges faced by HVACR contractors amid the refrigerant shortage. It offers FAQs, A2L refrigerant safety training, guidance from manufacturers...
May 21, 2025
Chemours
the_chemours_company_logo
Chemours partners with Navin Fluorine to manufacture Opteon two-phase immersion cooling fluid, addressing data center heat and energy demands. The collaboration supports commercializati...
May 7, 2025
230624520 © Chalermphon Thiamthat | Dreamstime.com
dreamstime_xxl_230624520
Lawsuit filed by HARDI and AHRI challenges NYSDEC's amended regulations on refrigerants, arguing for proper stakeholder input and adherence to EPA timelines.
April 9, 2025
203786694 © Chalermphon Thiamthat | Dreamstime.com
dreamstime_xl_203786694
A 57-year-old CEO from Georgia is charged with violating the AIM Act by unlawfully importing 500 cylinders of HFCs from Peru. This is the second prosecution in the US under the...
March 21, 2025
Pheonix Energy
phoenix_energy_logo
Phoenix Energy Technologies and Hussmann Corp. join forces to introduce Refrigeration IQ Powered by StoreConnect, an advanced refrigeration solution leveraging AI to reduce refrigerant...
March 12, 2025
322337856 | And © Bancha Singchai | Dreamstime.com
Refrigerants with low global warming potential are more sustainable for the planet, but often more flammable than traditional HFCs. UL Solutions’ Zhongshan laboratory is addressing safety concerns with new testing capabilities.
In response to flammability risks, UL Standards have been updated to establish new requirements regarding flammable refrigerant leak-detection systems. This includes A2L and A3...
March 12, 2025
195436771 © Yurii Malashchenko | Dreamstime.com
dreamstime_xl_195436771
HFC & blends segment to account for fastest growing segment, in terms of value, of the global refrigerants market during the forecast period.
March 7, 2025
NASRC
nasrc_logo
The Natural Refrigerant Training Summit is part of R-TRADE, the nonprofit’s workforce development initiative to improve technician recruitment, training and retention.
March 4, 2025

Finding Alternatives to R-22

As the clock ticks down to 2020, and the day when R-22 is no longer available, we asked leading refrigeration contractors and supermarket exectives about their preferred replacements. Comments were made during our 2013 Refrigeration Roundtable meeting durind 2013 Comfortech.
Aug. 5, 2014
4 min read

As the clock ticks down to 2020, which, for now is the date when HCFC R-22 is no longer available (in fact, some are predicting shortages in supply in 2015), we asked leading refrigeration contractors and supermarket exectives about their preferred replacements. Comments were made during the 2013 “Refrigeration Roundtable” meeting during Comfortech 2013.

Joe Gallego, Bay State Cooling: “I think most supermarket chains are onboard with the fact that 2020 is fast approaching, and R-407A seems to be the replacement refrigerant of choice. We haven’t really had to change expansion valves or tweak the systems much at all, other than adjust suction pressures here and there.”

Richard Luhm, Memphis Mechanical: “We’ve had some customers switch to R-407F early on, and during the learning phase of that period, it had quite a bit of glide to it, but it seemed to work fine. I think the particular program that they obtained the refrigerant by was certainly favorable, because it was free, to do at least three stores’ worth.
“We’ve had some small supermarkets that are challenged financially do some retrofits based on times of need. We’ve done some with MO99, and they worked very well. I’m not sure of the carbon footprint and all of that aspect of it, but as far as operation, the customers are very happy with the way it’s operated.”

Q: If R-22 is on the way out, we have R-407A, R-407F, R-407C and R-427A as man-made options. What of “natural” refrigerants and systems, such as secondary loop cascade systems using carbon dioxide (CO2?)

A: Steve Hagen, Sprouts: “I think the secondaries cost too much and use too much energy. I don’t think that’s going to be a long-term solution for anybody. I thing you’re going to find some people go the route that H.E.B. did recently, with self-contained propane cases. I think you’re going to find transcritical be the primary system used in colder climates. You’re going to see a lot of people interested in the ammonia/CO2 combination systems, both for their energy efficiency, and the fact that they’re natural refrigerants. As long as they manage the charge, and they’ve got a place that’s a little bit above ground level, for leak management, I think you’ll see a lot more of them show up in the next few years.”

Paul Burd, Weis Markets: “Our current store design is glycol secondary for medium temperature, and DX for low temp. We’re seeing maybe a 1% premium for energy, and big savings in reduction of service costs.”

Brad Morris, Giant Eagle: “We’ve used CO2, secondary CO2, and glycol for low to medium temperature  systems. Some of the selling points with those systems were, there’s supposed to be a reduction in maintenance costs with secondary systems, and piping and installation.

“With the secondary glycol systems, Giant Eagle has seen about a seven percent increase in energy consumption, based around the pump, and the parasitic load of the pump itself. Some of the stores with the secondary CO2 system seem to be doing better in terms of energy efficiency, so, I think there’s something there that we’d like to look into a little further on with the secondary CO2 for low temperature.”

Steve Wright, Wright Brothers: “We service one cascade CO2 system, which was procured  by our customer, and had been off for some period of time. Basically, we had to go from initial start-up. The folks from Kysor/Warren helped with information that we needed to get it started. It’s been running like a top. Water consumption is substantially higher, because it uses an evaporative condenser rather than an air-cooled condenser. It’s been a good system from operational and maintenance standpoints.”